The Intergraph Process, Power & Marine support team has posted CADWorx Plant 2016 Service Pack 2. This Service Pack is now available for download from Intergraph’s Smart Support System.
To access this Download from the Intergraph Smart Support:
- Log on to Intergraph’s Smart Support web at https://smartsupport.intergraph.com/
- Select View Downloads
- Select CADWorx Plant.
- Select Service Packs and Fixes.
- Select the download icon or the file link of the Hot Fix.
If you have trouble accessing this download or need further information, please send us an email us at support@ecedesign.com and we will be happy to assist you.
Note: This Service Pack does not require the installation of the previous Service Pack or Hot Fix.
CADWorx Plant 2016 Service Pack 2 Items Resolved
- Users can now use full range of AutoCAD color numbers in the Project-level Layer Manager.
- TPS metric-inch support for CWTPSPOSITION – Fixed issue causing inaccurate elevation capture when using TPS in Mixed unit (Metric-Inch) environment
has been fixed. - I-Configure 2014 SW and THRD Tee’s show one end as BW in ISO.
- Out of the box (OOTB) specifications had Pipe component end-type set to BW table. This forces BW end-types into extracted isometrics displaying BW ends instead of THRD or SW engagement when connected to THRD/SW components. OOTB specs were updated to remove the BW association on pipe Components so pipe end types on the extracted isometrics are driven by component connectivity instead.
- Selecting “PREVIOUS” In a AutoCAD Command – Using the [P]revious option in AutoCAD selection command was not selecting all previous components.
- CADWorx issues with restricted access – Fixed issue causing program issues when user has read-only access to Program Files folder has been fixed.
- CW P&ID View not linking using SQL data base – PIDVIEW now also supports SQL server.
- Structural plate moves from the center line of TPost during CEDIT of support – Fixed issue causing structural plate components used in pipe support assemblies to shift position after
CEDIT on the assembly has been fixed. - Delete Drawing Command not consistent – Fixed issue causing delete drawing prompt to be out of sync with drawing selection has been fixed.
- CONVERTSOLID/CONVERTENHANCED Issue – Fixed issue causing error on CONVERTSOLID or CONVERTENHANCED when the applicable PRJ is not loaded has been fixed.
- Add parts for steel plates details text grayed out for plate length and width UI for steel plate parts length and width in the pipe support modeler has been updated not to appear disabled.
- PCFIN not bringing flanges correctly – PCFIN has been enhanced to work with PCF files containing white lines (incorrect syntax).
- Nozzle Layout Angle should not affect Nozzle Ext Direction Angle – Fixed issue causing Nozzle layout angle to adjust when Nozzle Extension Direction Angle value is set has been fixed.
- Weight Calculation for Bent Pipe corrected
- Spec Breaks being inserted incorrectly- Fixed issue causing inaccurate spec breaks in some cases on isometric extraction has been fixed.
- CONVERTFROMPRJDATA changes end preps – Fixed issue causing Long Description end prep suffixes in some cases to be altered fixed
- CONVERTFROMPRJDATA not updating Components to work when PRJ files have been renamed from when components were first modeled has been fixed.
- CONVERTFROMPRJDATA/CHANGESPEC not working on certain union type components has been fixed.
- Legacy keywords {LENGTH} keyword on nipples to get reset to {LENGTH} text when connecting to unions has been fixed.
- nozzle on nozzle w/ name change – Modifying Equipment names now cascades to nozzles on nozzles.
- Useful keyin commands no long available MAIN, RED, SPEC keywords are now available in CADWorx Plant.
- TopWorks Mirror Issue preventing mirror option in TOPCHG command from applying has been fixed.
- The sketch in data table for Slip On flange was incorrect and has been updated.
- The sketch for THRD and SO flange sketches has been updated to show the PENG variable
- Line Number drop down list issus resolved.
- 3D Graphics and centerline detachment issues resolved
- Pipe Supports inserted as hidden until REGENERATEPIPESUPPORT was run has been fixed.
- Radius on bend still placed using the TUBE command even when the bend radius is smaller than the bend radius specified by the user has been fixed.
- CONVERTCADWORXLEGACYDWGS issues when running on Windows 8/8.1 64-bit OS and AutoCAD 2015 has been fixed.
Hard coded end preps in Long Description replaced when that end prep was specified in the specification, and also added during placement has been fixed. - Centerline of Pipe Support does not move if part of Xref resolved
- CONVERTFROMPRJDATA changes half coupling incorrectly resolved
- Elbowlet projections are now calculated correctly for any radius elbow.
- Have CHANGESPEC look at rating also Mating valve/flange rating is now considered when using CHANGESPEC when multiple flange options are available.
- CADWorx Restraints showing up in 2DREP – 2DREP solids only option has been updated to eliminate 2D restraint symbols.
- Custom Data Updates
- Spec View Palette updated to show long description even if Reduction Size not set.
- Clash View Palette updated to fix ignore Xref’s checkbox.
- Nip-O-Let component catalog thumbnail has been update.
- BOMEXPORT Accumulation for Mitered Elbows
- Angle valve SKEY can now be used with User Shapes.
- Added ability to attach Plant User Shapes to Equipment Nozzles
- CONVERTFROMPRJDATA has been fixed in regards to bolts
- DiscontinuityView now detecting all “Unconnected” flanges
- Automatic bolts coming in on the wrong line number corrected
- Fixed Auto bolt and Line Number issue in regards to gaskets.
- Fixed issue with Cut/Paste on component nozzle
- Fixed issue with right-click Cut/Paste on Equipment nozzle has been fixed.
Fixed ELEMENT component and ISO discontinuity issue - Fixed REASSOCIATEMODEL Command and Skewed Piping
- Fixed issue with Usershapes losing Endtypes and causing disconnects in Isogen
- REPLACEPIPESUPPORT command has been enhanced to dynamically update pipe support assembly listing when new support assemblies are added during the session.
- Generic Attach created cannot use “GCE” command fixed
- Fixed issue causing component list description for reducers to reflect Tee descriptions when Branch Table rule permits only Tee + Reducer at current main by branch size has been fixed.
- Fixed False Positive Command Line Error “Could not open project spec file” even when PRJ file was loaded fine has been removed.
- Fixed issue where SKEY to be ignored when IDENTIFIER is PIPE
- Fixed issue where Gasket & Bolt weights not included in C2OUT
- Fixed issue causing data table weight for Double Angle being doubled on placement has been fixed.
- Fixed issue where Continuation Graphic setting produced incorrect Isometrics
- Fixed issue where BOMEXPORT command unable to create output file if foot mark (‘) in custom field text
- Fixed issue where custom pipe support assembly stored in the model was missing component weight
- Enhanced product to allow Custom Field data to export to SQL server DB.
- Fixed issue preventing “Save to Model” on pipe support assemblies in some cases.
- Fixed issue preventing REPLACEPIPESUPPORT command from executing against pipe support assemblies previously updated using the REGENERATEPIPESUPPORT command
- Fixed issue causing “Existing” option to be disabled when GCE is used to change line number on a selection set containing both “Existing” and non-“Existing” components has been fixed.
- Fixed issue where you are unable to select components in CADWorx IP in some cases
Please note that the complete document can be found on Smart Support.
Leave a Reply
You must be logged in to post a comment.